XLS Series
Minimum Guaranteed Power per channel, both channels driven | |||||
XLS 202 | XLS 402 | XLS 602 | XLS 802 | XLS 5000 | |
1 kHz with 0.5% THD | |||||
Stereo, 2 ohms (per ch.) | -- | -- | -- | -- | 2,500W** |
Stereo, 4 ohms (per ch.) | 300W | 450W | 600W | 800W | 1,800W* |
Stereo, 8 ohms (per ch.) | 200W | 300W | 380W | 500W | 1,100W* |
Bridge-Mono, 8 ohms | 600W | 900W | 1,200W | 1,600W | 3,600W* |
Bridge-Mono, 4 ohms | -- | -- | -- | -- *750W for 100V models | 5,000W** *with 0.1% THD **with 1% THD |
- Reliable design incorporates many popular features
- Reliable design incorporates many popular features
- Housed in a rugged, all-steel 2U chassis (3U in the XLS 5000)
- Efficient forced-air fans prevent excessive thermal buildup
- Electronically balanced XLR inputs; touchproof binding post and Speakon® outputs
- Precision detented level controls, power switch, power LED, and six LEDs which indicate signal, clip and fault for each channel.
- Three-Year, No-Fault, Fully Transferable Warranty completely protects your investment and guarantees its specifications
Specifications
Sensitivity (volts RMS) for full rated power at 4 ohms |
1.25
|
Frequency Response (at 1 watt, 22 Hz - 20 kHz) |
+0 dB, –1 dB
|
Signal to Noise Ratio below rated power (20 Hz to 20 kHz, inputs terminated) A-weighted, below rated power No weighting, below rated power |
> 100 dB
> 95 dB |
Total Harmonic Distortion (THD) at 1 full bandwidth power, from 20 Hz to 1 kHz |
< 0.5%
|
Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1, from full rated output to –30 dB |
< 0.3%
|
Damping Factor (8 ohm): 10 Hz to 400 Hz |
> 200
|
Crosstalk (below rated power) at 1 kHz at 20 kHz |
–75 dB
–50 dB |
Input Impedance (nominal) (balanced, unbalanced) |
20 kilohms, 10 kilohms
|
Load impedance Stereo Bridge mono |
4-8 ohms
8 ohms |
AC Line Voltage and Frequency Configurations Available (± 10%) |
120 VAC 60 Hz
100 VAC 50/60 Hz 220 VAC 50 Hz 230-240 VAC 50 Hz |
Ventilation |
Flow-through ventilation from front to back
|
Cooling |
Internal heat sinks with forced-air cooling
|
Air Volume Requirements (per minute per unit) |
80.15 ft3 (2.27 m3)
|
Dimensions: Width, Height, Depth |
XLS 202, 402, 602, 802: EIA Standard 19"W (EIA RS-310-B) x 3.5” (8.9 cm) H x15.2" (38.6cm) D.
XLS 5000: EIA Standard 19"W (EIA RS-310-B), 5.25” ( 13.3 cm) H x 15.5” (39.5 cm) D. |
Net Weight, Shipping Weight |
XLS 202: 23.0 lb (10.4 kg), 28.0 lb (12.7 kg)
XLS 402: 25.7 lb (11.7 kg), 30.7 lb (13.9 kg) XLS 602: 29.0 lb (13.2 kg), 34.0 lb (15.4 kg) XLS 802: 35.5 lb (16.1 kg), 40.5 lb (18.4 kg) XLS 5000: 62.0 lb (27.7 kg), 74.0 lb (33.6 kg) |